If you fail to install two modules, you might receive spurious OUTPUT FAIL indications on the power supply. Table A-11 1300 W DC-Input Power Supply Specifications. Backordered. 13.For operation in Japan, ask your local electrical contractor to prepare the NEMA 6-20 power plug. Skip Content. For additional information about the power management feature and individual module power consumption, refer to your software configuration guide. ), Ciena 4200 series, Ciena 6500 and Ciena 8700 series. 2.For use with the Catalyst 6504-E switch only. Ciena’s 6500 Packet Transport System (PTS) addresses the growing need to maintain profitable delivery of TDM services while future-proofing investments toward an all-packet network modernization. Table A-40 lists the relay controller box relay type, the corresponding power supply terminal block positions, and a description of the power-cycling operation. Table A-36 6000 W Power Supply AC Power Cords, Japan, North America 100–120 VAC operation31. Products and services; Network insights; Sales and support; About us; All products Overview Features Specs 3D demo Support and next steps. 3.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-1 Catalyst 6500 Series Power Supplies. See the power supply specifications tables for the AC power cord illustrations that are applicable for your power supply. Similar. The 8700 W power supply cannot be installed in the Catalyst 6503, Catalyst 6503-E, and Catalyst 6504-E switch chassis. If the power supplies are of unequal wattage and the higher-wattage supply is removed, the lower-wattage power supply must be turned on manually. Contact Us. $22.00 shipping. – INPUT 1 and INPUT 2 both connected to low-line (120 VAC nominal), – INPUT 1 connected to high-line (230 VAC nominal); INPUT 2 not connected, – INPUT 1 not connected; INPUT 2 connected to high-line (230 VAC nominal), – INPUT 1 connected to high-line (230 VAC nominal); INPUT 2 connected to low-line (120 VAC nominal), – INPUT 1 connected to low-line (120 VAC nominal); INPUT 2 connected to high-line (230 VAC nominal), – INPUT 1 and INPUT 2 both connected to high-line (230 VAC nominal). – The 1300 W, 1400 W, 2500 W, 2700 W, and … Table A-5 950 W AC-Input and DC-Input Power Supply LEDs. Power supply blank panel—The power supply blank panel must be installed on an unused power supply bay to maintain chassis airflow and EMI shielding. We also offer repair services on a large range of Ciena products. Note The 6000 W DC-input power supply is limited to 4000 W maximum output when it is installed in a Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB switch chassis. Table A-11 lists the specifications for the 1300 W AC-input power supply. Cooler Master Power Supply; Dell Power Supply; ... NTK560CJ Ciena Ome 6500 32 Slot Shelf Base. The 8700 W AC-input power supply, shown in Figure A-18, shares a similar, but not identical, form-factor as the 1000 W, 1300 W, 2500 W, 3000 W, 4000 W, and 6000 W power supplies. The total available wattage is the output wattage of the higher wattage power supply. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. Table A-39 8700 W AC-Input Power Supply LEDs, – For +3.3 VDC output: 2.7–3.0 VDC (min); 3.6–3.8 VDC (max), – For +12 VDC output: 10.5–11.5 VDC (min); 12.6–13.0 VDC (max), – For +42 VDC output: 38.0–40.0 VDC (min); 45.0–52.0 VDC (max). 30.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-28 4000 W AC-Input Power Supply Specifications. Note For proper load-sharing operation in a redundant power supply configuration, you must install two modules in the chassis. Note The 4000 W DC-input power supply requires two source DC-inputs to be connected; it cannot operate with only one positive (+)/negative (-) source DC terminal pair installed. Ciena’s field-proven WaveLogic programmable coherent interfaces give you a full suite of plug-and-play high-capacity solutions that offer the widest range of tunable capacities, significantly improving transport economics with the ability to scale to 800G. Note Because of the form-factor difference, when you install an 8700 W power supply in a Catalyst 6506, Catalyst 6509, or Catalyst 6509-NEB chassis you must relocate the system ground connection from the chassis ground pad connection to the two system ground studs located on the 8700 W power supply faceplate. Table A-11 lists the specifications for the 1300 W DC-input power supply. Note All 950 W power supply power cords have an IEC60320/C15 appliance connector at one end.