chime trans-former, or the LEE DAN transformers specified, voids all guarantees! 5 HANDLING 5.1 COMPLETE TRANSFORMER Total weight iii. endstream endobj startxref Develop a procedure for inventory of all tools, hardware, and any other objects used in the inspection, assembly, and testing of the transformer. Les instructions suivantes se déroulent en trois étapes : Téléchargement de PDFCreator; Installation; Conversion en JPG Plan for the prevention of contaminants. Check the transformer nameplate and verify that it is the correct kVA, frequency, line and load voltage for the application 3. Part 3 will cover installation procedures for liquid-filled transformers that are shipped unassembled. Current transformer (CT) Installation Instructions. Transformer Installation, Operation, and Maintenance Manual ... Use proper lock-out/tag-out procedures. There are many types of transformers like oil type, dry type etc. 0000003326 00000 n 0000049053 00000 n Erection Procedure for Power Transformer. GPCP-CT-INST . %%EOF TRANSFORMER INSTALLATION PROCEDURE 1 Scope The scope of this procedure is to provide general guidelines for receiving; installation; and baseline testing prior to initial energizing of all relocated and new substation class transformers, shunt reactors, large voltage regulators and other similar oil filled devices. 189 31 Remove the cover over the wiring compartment. 1.3.1. Posted 9th November 2017 29th March 2019 Admin. Necessary confined entry procedures should be followed in compliance with company policy or local regulations. 2 Installation and instructions | Dry-type transformers World leadership ABB is a world leader in transformer manufacturing, and our transformers can be found in countries all over the world. Responsibility for correct storage lies with the customer. Transformer - IMPORTANT!Connecting this equipment to any power source other than a standard 16VAC. Acceptance and initial inspection It is important that a thorough inspection of the transformer be made before it is unloaded from the carrier. 6.3.1 All the activities are done manually. 㿙@����X�����g�0 ��>� The windings Transformer windings are subject to continuously high electrical and mechanical loads. 0000045544 00000 n Version number: 1 To minimize environmental contamination and fire hazard, users are specifying dry-type transformers more and more frequently. INSTALLATION PROCEDURE . Transformer as energy converter dissipates losses; depending on operation of the unit (load characteristics) the losses can have significant economical cost for users. 0000003567 00000 n This article will continue in subsequent issues of EC&M. The information contained herein may not cover all variations in equipment or provide for all contingencies which might be met in installation, operation and maintenance. the equipment, procedures, or process described, nor to provide directions for meeting every possible contingency during installation, operation, or maintenance. PCP-CT-INST Current Transformer Installation Procedure 1 of 3 MODIFICATION OF THIS DOCUMENT MUST BE AUTHORIZED BY PROTECTION & CONTROL TECHNICAL SERVICES PROCEDURE. 0000003289 00000 n A+ 0 Go back to Installation Guidelines ↑ 4. h�b```f``2e`a`�Qf�g@ ~�+s,pdPXwH��K�ڀ���j`0�6}2����׮;)�\��VTu녋��0(K3����!������A)�������1�����( �e`�sH����0>� The unit will be inspected prior to shifting to site for any mechanical and structural damage during transportation. Develop a procedure for inventory of all tools, hardware, and any other objects used in the inspection, assembly, and testing of the transformer. CURRENT TRANSFORMER . 3). When the transformer core is ready, a hydraulic platform moves it into the vertical installation position in which the windings are assembled. 7.3.6 Go through the installation manual of the 33KV Transformer for essential details regarding tools, reporting damages and so on. Pigtail: A PS-3A or PS-3B type transformer … The hold-down nuts are designed to be loosened, not removed. This guide is necessarily general in nature. PDF Transformer 2.0.1147.4932 est disponible gratuitement au téléchargement dans notre logithèque. Shop drawings will include front and side views of the equipment, overall dimensions, components identity, components type and ratings, electrical characteristics, incoming and outgoings location details among others. Convertir un document Word au format PDF Si Word est installé sur votre ordinateur, ouvrez le document Word (.doc,.docx), ou tout autre fichier lisible par Word, que vous voulez convertir. x�b```b``~�� During installation of Transformer on a Pole mounting structure, following checks should be made: 1. Grâce à ces quelques lignes, vous pourrez convertir un document Word, Excel ou un PDF (ou un document de n’importe quel logiciel) en JPG (ou en PNG, ou d’autres formats d’images). 0000009716 00000 n transformers are becoming more popular because the higher cost of underground distribution is being offset by increased interest in aesthetics, safety, and system reliability. ��6�clo�&46�g�3��g/�;*�;�00�h0:� Avant de commencer le nettoyage, s’assurer que les appareillages électriques sont conçus pour être nettoyés avec de l’eau. Par exemple PDFCreator, que vous pouvez télécharger sur Commentcamarche.net à cette adresse. xref 0000006891 00000 n 4 Fix the protection terminal with the big screws. Indépendamment de votre version de Word, vous pouvez utiliser un logiciel dédié qui fonctionne comme un pilote d'imprimante. Any item found missing or damaged will be noted to the supplier immediately for the replacement / repair. Losses are divided into: •no-load loss •load loss Transformer also consumes some auxiliary power, resulting in auxiliary losses Transformer Consulting Services Inc. Transformer Design: Loss Evaluation . Important note // If the transformer is moved or if it is stored before installation, this inspection should be repeated before placing the transformer in service! transformer completely by filtration procedure . Ouvrez le fichier Word à convertir en PDF et appuyez simultanément sur les touches Ctrl et P du clavier. PPE: 8.1 Electrical … An article on how to choose a transformer based on the latter criteria appeared in the May '96 issue of EC&M. 1. Au bou… Page No. #1��E? 0000049218 00000 n 4 Transformer Installation, Operation and Maintenance Manual 004-0987-000 n Check all bolted electrical connections, including taps. Testing and Commissioning Procedure for Electrical Installation 1. Prior to installation, the foundation will be checked for cleanliness and level. GPCP-CT-INST . et à transformer, elle sert aujourd’hui à chauffer, ... sur une installation électrique, à moins qu’elle ne soit pulvérisée ou que l’installation soit hors tension. If applicable, remove the cover over the wiring endstream endobj 64 0 obj <> endobj 65 0 obj <> endobj 66 0 obj <>stream Safety. 219 0 obj <>stream Total cost iv. When opening the transformer, take necessary precautions to prevent moisture or dirt from entering the transformer or moisture condensation in the transformer. 0000007045 00000 n For additional information, contact your Eaton representative. En un clic, ABBYY PDF Transformer + enregistre votre fichier PDF au format texte ou tableur (Word, Excel, HTML et TXT), permettant ainsi d'en exploiter les ressources. 0000003501 00000 n 7. 4 Transformer Installation, Operation and Maintenance Manual 004-0987-000 n Check all bolted electrical connections, including taps. Version number: 1 Approval date: 10/10/2012 Authoring department: Generation Protection & Relay Support Approved location: P8 File name: GPCP-CT-INST . hޤT[k�0�+�q{�t�%�PI�t��uX!n�%�[e����|�����ѹ�H:��@AQ`" ŀ���_rP>0j-J �J������>;#�"-�h�5n*��(�����\F&6h���P�En�n��x��Y��3jQb��s^�H�%��O�B?2�⭞�����?z�if��X�C�ױ���&�q\� �+��s���V�F�Q����~��,����rR�k�phcG�Z�T��$���vg��PJ�ump&�4��x���x\. Before the transformer is stored, a full check as described in the ‘Acceptance procedure’ paragraph should take place. CTs should only be installed or maintained by competent individuals. 7.3.7 Inspect the routing of the floor cutout cables to ensure they follow the exact drawings and specifications. 0000006578 00000 n Go back to Installation Guidelines ↑ 4. If we choose high value of ‘r’then flux will be high, so large cross section is required which will increase volume, weight and cost of iron and also give higher iron loss. Also there is detailed analysis about the consisting of a distribution transformer. Total volume ii. Also information about some types of transformers are gathered as well as distribution transformer connections installations. La procedure d'installation de ReportLab fonctione parfaitement, merci à toi de la part des debutants python galerant avec les librairies d'install. Une fois le logiciel installé, il figure dans la liste de vos imprimantes. Important note // If the transformer is moved or if it is stored before installation, this inspection should be repeated before placing the transformer in service! CURRENT TRANSFORMER . 60° angle between them (Fig. Plant and Equipment. 189 0 obj <> endobj Plan for the prevention of contaminants. 0000048034 00000 n •The way a transformer is handled and the procedures that are used to receive, assemble, process and test the transformer are of fundamental importance to the long life of the transformer. Introduction The procedures stated in this document cover the activities in preliminary tests and inspections, functional performance tests and the commissioning of newly completed installations and existing ones after major alteration. 0000006732 00000 n Do this before the installation of the 33KV transformer. Additionally, after the transformer is placed in permanent position, Installation Procedures 1. Inspection prior to energizing After a transformer is moved, or if it is stored before installation, the inspection should be repeated before placing the transformer in service. 0000006099 00000 n 0000001928 00000 n Mechanical installation Installation 4.2.1 Mounting procedure 1 Cut and affix the sealing strip if IP 54 is required. 0000004969 00000 n n Ventilated models: loosen core and coil hold down nuts (Figure 1) to reduce possible sound transmission to the case. 0000006014 00000 n This method statement explains and covers the transformer installation & inspection procedure of cast resin Transformers, although it is applicable for any other type as well. installation, commissioning and maintenance of oil-filled transformers. %PDF-1.3 %���� Part 2 will address installation procedures for dry- and wet-type transformers, the latter being fully assembled. The fasteners may have loosened during shipment. Transformer is used to transform the high voltage powers to low voltages, so that it is useful for domestic purpose. 0000045768 00000 n Total loss All these quantities vary with ratio r = ф m/ AT. 6. 0000005422 00000 n 0000019446 00000 n 0000006420 00000 n For additional information, contact your Eaton representative. 0 Plug-In: A PS-20A plug-in type transformer may be used and must be provided with an electrical outlet at some convenient location within 50 feet of the master station. startxref Changing this document also affects a summary pdf entitled Summary of Transformer Documents. 63 0 obj <> endobj Disk and cylindrical coils … 2. The transformer shall be lifted by using the eyebolts loca-ted on the upper supports and cables long enough to get max. • The transformer must always be stored filled with liquid 1 - GENERAL 1.3 Transportation Distribution transformers are shipped ‘ready for installation’, which means they are filled with the insulating liquid and with accessories fitted. 0000005818 00000 n The successful operation of a transformer is dependent on proper installation as well as on good design and manufacture. 0 trailer CTs can be installed in systems were lethal voltages are present. Close attention should be paid to the following: transformer has been moved to the installation site or some other convenient location to permit inspection of the internal assembly for damage in transit, proceed as outlined in “Internal Inspection.” Request that a representative of the carrier be present during the inspection. 0000001843 00000 n 3 Fasten the side holders to the back of the protection terminal with the small screws. 5. 37 6.1 Diagram of the user installation 40 6.2MV switchgear solutions 42 7. Pour l'installation du programme, vous trouverez habituellement les fichiers d'installation sous les noms suivants : PDFCreator.exe, PDFTransformer.exe et Transformer.exe. The resin transformer is intended for indoor installation, therefore it must not be stored outdoors. Transformer may be designed to make one of the following quantity as minimum i. Transformer Design Dry-type and cast resin, protection methods are being referred and more also included in the specific research document. Prior to commencement of transformer installation work, all shop drawings will be processed and submitted for approval by consulting engineer. 0000002290 00000 n $=@ (�����q�M�G��g�"C�!����F��"1�l��yg��԰�w�@�����gy/�p�g�/�$���'���S��ᑪ�����ī~�uWs[^��s�h@�A1X]�WPy�B�J���}D�v\���՚p��o�Ƒ�N9��YO�y ��.���qla�kTiQ�9,W����*aa#�[��c>��9X. The name plate will be checked against equipment data sheet to confirm conformity with the approval. GENERATION . This technical article deals with transformers and their installation so we restrict ourselves here to the procedures associated with their commissioning.Transformers should be inspected for internal or external damage, particularly if they have been dropped or tipped over. Ensure the area is well ventilated and free from explosive or corrosive gas or vapors. 0000046787 00000 n Changing this document also affects a summary pdf entitled Summary of Transformer Documents. Acceptance and initial inspection It is important that a thorough inspection of the transformer <<034D7887CA6B9E41820942647BDB1F4E>]>> SOP/---/--/PM -01 STANDARD OPERATING PROCEDURE Effective date DD.MM.YYY Review date Supersedes MAINTENANCE – TRANSFORMER Issue No. 4.3 Semi-flush mounting Fig. Transformer Connections, Distribution Transformer Manual by General Electric, RUS++ by Alexander Publications, and Transformer Connections by General Electric. Choisissez alors PDFCreator dans la liste des imprimantes et cliquez sur Imprimer. 2 Put the protection terminal in the cut-out. Shut off primary voltage using approved lock-out/tag-out procedures 5. q� 0000003723 00000 n v Revision Log 0 10/10/2012 Original procedure file “GPCP-CT-INST” created … Transformers: Basics, Maintenance, and Diagnostics vii Contents (continued) Page 4. 0000002894 00000 n 0000047016 00000 n installation procedure for transformers Where auxiliaries are shipped loose, these will be identified and checked against the dispatch documents. 78 0 obj <>/Filter/FlateDecode/ID[<763A4BD8572906AEAA32DF5FAF823FE0><6F5AED44863C584BBB90B90D6D776B88>]/Index[63 26]/Info 62 0 R/Length 80/Prev 108988/Root 64 0 R/Size 89/Type/XRef/W[1 2 1]>>stream INSTALLATION PROCEDURE . Do this procedure once in a year STOP Document No. the equipment, procedures, or process described, nor to provide directions for meeting every possible contingency during installation, operation, or maintenance. 88 0 obj <>stream Shut off primary voltage using approved procedures. h�bbd``b`z$�� ��2 BH0׃X1 Bĵ�KA���w�������pd After reviewing the risk for any particular installation all required precautions should be taken. 0000005597 00000 n Transformer Installation Method. %PDF-1.5 %���� Product literature and application advice were provided by ABB Power T&D Company Inc., Alec Wolowidnyk, Arkansas Electric Cooperatives, BC Hydro, Cooper Power Systems, ERMCO, General … %%EOF Mount the transformer securely 4. Check whether tests are carried out for – Ratio Tests, % impendence voltage test and rate voltage withstand tests . 0000000916 00000 n DOCUMENTATION 7.1 Keep the service report at Substation and Notice the BDV value and Due date in near Transformer 8. 0000000016 00000 n transformer can be readily accomplished at a suitably clean and dry location on the site. Tighten if loose. The fasteners may have loosened during shipment.